Primary limit switch It is an automatic reset, temperature sensor. Free shipping on orders over $99 Provided that the fan switch is in AUTO position, when the thermostat has been satisfied and turns off the oil or gas burner at the furnace, the fan limit switch will cause the blower or fan unit to continue to operate just until the temperature at the supply plenum has reached or dropped below the FAN OFF lower limit on the switch - the blue 1-piece Vinyl Caps (1) Auxiliary Limit Switch (1) Button Plug (1) Drain Trap (1) Flame Sensor (1) Hose Clamp (1) Interlock Door Switch (1) Manual Reset Limit Switch (1) Natural Gas Orifice (1) Pressure Switch (1) Primary Limit Temperature Control (1) View Port Bushing (1) Mar 19, 2016 · Goodman-Amana 10728305 - Primary Limit Switch- Primary Limit Switch. Shop now and get same-day shipping on this 20162904 Limit Switch. This Goodman 20162903 Primary Limit Switch 150F is a genuine OEM repair part. Shop now and get same-day shipping on this 49L88 Limit Switch. Visit the Goodman Store. 49. Extensive product details, fast shipping, and expert support Goodman-Amana 20162906SP - Primary Limit, 20162906SP- 20162906SP is an official OEM Primary Limit for Goodman-Amana HVAC equipment. 0 out of 5 stars 4 It shows that the primary limit switch is open (one light on. They are really for downflow furnaces, so in your case, if/when you find it, you can bypass it and leave it. This 10123539 manual reset limit switch is rated for 240℉ and is a guaranteed genuine Goodman OEM replacement for several Goodman, Amana, and Janitrol units. Expert. The installer put whole new ducting for it. Primary thermal limit switch 1370910S turns off the burner if the burner gets too hot. The rollout limit switch, activated when the burner flames are not being properly drawn into the heat exchanger, must be manually reset. SKU: Goodman-Amana 20162903 - Limit Switch- Limit Switch. Where do I find these 2 limit switches Contractor's Assistant: Did you check the furnace's filters? Customer: m/n 80UHG3/4-100A-3 FILTERS look good Contractor's Assistant: Do you plan on doing the work yourself? B1370189 Furnace Primary Thermal Limit Switch Genuine Original Equipment Manufacturer (OEM) Part. 80 $168. Service. I have a Lennox G40UH-36C-110. $13. But, again, we must stress the importance of the limit switch and why you should keep it in the best working condition at all times. Mike. Feb 7, 2008 · Gas and Oil Home Heating Furnaces - Lennox furnance turns off. Replace the primary limit switch on your Goodman furnace with this replacement switch. . Free shipping on orders over $99 Auto Limit Switch (120F - 130F), 0130F00038S. Sep 14, 2012 · Buy Goodman 20162903 160°/120° Primary Limit Switch: Automotive - Amazon. Buy Goodman Amana 20162904S Limit Switch - Primary for your Goodman Amana Furnace new from the technical experts. This safety switch monitors the burner flame and is located on the burner assembly. Jan 1, 2025 · Limit switches get their name from the original job that they were designed to do. 1 star 2 stars 3 stars 4 stars 5 stars. Safety: As a safety device, the role of a limit switch is to shut off the gas supply to the furnace burners, to prevent furnace and heat exchanger overheating. 30 $ 50. Limit Switch - Primary L160°F -30°F (TOD #60T81-314368) Description: Primary Limit Switch, 160F; I'm getting a primary/secondary limit switch code from my furnace and a bad smell. In this episode of Repair and Replace, Vance shows how to replace the high limit switch in a gas furnace. Find OEM Goodman 20162904S PRIMARY LIMIT SWITCH FURNACE replacement part at Parts Town with fast same day shipping on all in-stock orders until 9pm ET. En español. GOODMAN Primary Limit Switch, 180 deg. Limit Switch, Primary, M1, M3, For Use With: Goodman and Amana Equipment GMS90453BXA, GMS90904CXA. – Limit switches are available in several switch configurations: Normally Open, Normally Closed, or one of each. Reliable and efficient, it is a critical component for HVAC maintenance. My Lennox G40UH is saying the primary/secondary limit switch is open. At the day one after the installation it started to show the notification "Primary Limit Switch Open": 845583 The installer was trying to convince me that it's normal and it will go away. Goodman-Amana 20162904S - Primary Auto Limit Switch, 20162904S- 20162904S is an official OEM Primary Auto Limit Switch for Goodman-Amana HVAC equipment. Lennox g40UH-36A-070-03 Goodman 20162904 Primary Limit Temperature Control $35. Use Ctrl+F to simplify your search. Shop our full selection of Goodman HVAC replacement parts. According to the diagnostic lights, as. Notify Me When Available. 36. Shut off the house circuit breaker for the furnace before installing this part. You're reviewing: Goodman 20162904S Primary Limit Switch Furnace Your Rating. com FREE DELIVERY possible on eligible purchases Feb 10, 2014 · This primary thermal limit switch (part number 1370910S) is for furnaces. 99 Aug 21, 2023 · Buy Primary Limit 0130F00036 Replacement for Goodman OEM: Limit Switches Furnace Limit Switch L150-40F fits for York Coleman, Replace 024-35596-000, 0243559600 This Goodman 20162906 M4 Primary Limit Switch is a genuine OEM repair part. Product DescriptionThe Bard 8402-146 Primary Limit Switch L185 is designed for HVAC systems, ensuring safety by regulating temperature limits. It also keeps track of operating temperatures to make sure the furnace doesn’t become too hot, as overheating is dangerous to both the furnace and the home’s occupants. 5. Free shipping on orders over $99 Your Zip: 98837 Goodman-Amana B1370188 - Primary Limit Switch (L170-30F), B1370188- B1370188 is an official OEM Primary Limit Switch (L170-30F) for Goodman-Amana HVAC equipment. Find OEM Goodman B1370190 L210-30F PRIMARY LIMIT SWITCH replacement part at Parts Town with fast same day shipping on all in-stock orders until 9pm ET. Free shipping on orders over $99 Your Zip: 23917 Dec 11, 2014 · This item: Goodman Primary Limit Switch, Light Blue . Additional information. This Goodman B1370190 Primary Limit Switch 210F is a genuine OEM repair part. Get it as soon as Friday, Jan 10. 88 $ 16 . Crown Boiler 16-829 - Primary Limit Switch, 16-829- Primary Limit Switch. $34. 22 $ 13. Weight: 0. Where is the primary limit switch so I can remove and attempt to clean or flick back into working correctly? Mar 6, 2017 · Genuine Original Equipment Manufacturer (OEM) parts! This burner roll-out limit switch (part number B1370145) is for furnaces. 22. $14. Service all Dec 22, 2024 · Repair your Goodman furnace with this primary automatic limit switch. 0 out of 5 stars 2 1 offer from $888 $ 8 88 Goodman-Amana B1370198 - Auto Limit Switch (120-150F), B1370198- B1370198 is an official OEM Auto Limit Switch (120-150F) for Goodman-Amana HVAC equipment. Free shipping on orders over $99 Your Zip: 23917 May 21, 2015 · Goodman B1370187 160°/130° Primary Limit Switch. Primary thermal limit switch B1370189 turns off the burner if the burner gets too hot. Goodman-Amana B1370920 - 7" Primary Limit Switch, B1370920- B1370920 is an official OEM 7" Primary Limit Switch for Goodman-Amana HVAC equipment. Primary thermal limit switch 1370914S turns off the burner if the burner gets too hot. MFG PART 20162904S. Get your furnace back up and running with DIY instructions and OEM replacement parts. Goodman B1370195 300°/270° Primary Limit Switch . Nov 3, 2014 · Primary/Secondary limit switch open for Lennox G26Q2-50-4 My furnace was blowing cold air so I looked the diagnostic light to determine th goodman GDS80703AXBC high limit switch Mar 11, 2020 · Empire Primary Limit Switch R1821 for Empire Floor Furnaces 3588-2, 5088-2, 7088-2. Goodman Furnace Primary Limit Switch. Genuine Original Equipment Manufacturer (OEM) parts! This primary thermal limit switch (part number B1370189) is for furnaces. Checked out furnace and warning lights. If you've already checked continuity or voltage on your primary limit and rollouts, and those are good, it's likely the secondary limit. PRIMARY LIMIT SWITCH 180 DEG PINK by Goodman. Cut Out 175°F Cut In 145°F. Brief content visible, double tap to read full content. Product information . Mar 11, 2023 · I had Lennox SLP99UHV installed back in 2020. Dec 27, 2024 · Goodman-Amana 20162904 - Primary Auto Limit Switch- Primary Auto Limit Switch. 29,691 Satisfied Customers. This video outlines the steps taken to a successful resol Johnstone Supply is a leading wholesale distributor for HVACR equipment, parts and supplies available and in-stock at local branches. Free shipping on orders over $99 Oct 16, 2021 · There you have it – a brief guide on open furnace limit switches. There are generally 4 types of limit switches that we classify into the following types: Lever; Plunger; Roller; Whisker Apr 15, 2019 · 47-22861-01 Furnace Limit Switch Thermostat L350 Compatible with Rheem Goodman Amana 10123532 101235-32 B1370154 Replace L350F SRL350 350F L350F L350MR, 1 PCS 5. 40 Add to Wishlist Compare Add to cart. – A limit switch is an electromechanical device consisting of an actuator mechanically linked to an electrical switch. 375 Clip, Blue (0130P00093) GOODMAN 20513001 Fitting-Evap Drain (20513001) GOODMAN Door Assembly (0261P00003) GOODMAN HIS Board with 9-Pin Connector (B1809913S) Mar 22, 2018 · (A) Primary/Secondary limit switch open, OR (B) WatchGuard mode-limit switch open longer than 3 minutes. BROMIC Heater Head Cover Tungsten Freestanding Heater - CUSTOM. Ships from and sold by Everything Home . Use with Models CGHA30AE 1 CGHA30AE 2 CGHA30AE 3 CGHA30AE 4 CGHA30AE 5 CGHA45AE 1 CGHA45AE 2 CGHA45AE 3 CGHA45AE 4 CGHA45AE 5 CGHA60AE 1 CGHA60AE 2 LF24-30A 1 LF24-30A 2 LF24-30A 3 LF24-30A 4 LF24-30A 5 LF24-45A 1 LF24-45A 2 LF24-45A 3 LF24-45A 4 LF24-45A 5 LF24 Goodman-Amana 20162906 - Primary Limit- Primary Limit. Orders less than $99 will have multiple shipping options starting at $4. Limit Switch Thermostat L350F fit for Goodman Amana Furnace 10123532 101235-32 B1370154 -Replace 36TX16 611871 SLR350 L350F 10123532 (2 PCS) 5. SKU: 0200-194-001P Goodman-Amana The Goodman Primary Limit Switch (L170-30F) is a crucial HVAC component, monitoring and regulating temperatures for safe and efficient operation. Buy GOODMAN GOODMAN LIMIT SWITCH PRIMARY (20162906) 20162906: Limit Switches - Amazon. ). Oct 19, 2023 · The primary function of a furnace limit switch is to continuously monitor the temperature within the combustion chamber or heat exchanger of the furnace. André R. 5 out of 5 stars 6 ratings. 4. It is programmed to reset automatically after a malfunction. Item # 312501714 | Goodman Part # 20162904S | UPC Code 193031202168 | UNSPSC Code 40101600 | Catalog Page #728. These areas can become extremely hot during heating, and the limit switch ensures that the temperature remains within safe operating limits. It services four zones. So to properly test them for continuity you would need to test them as soon as the 4-flash fault code presents. This item: Goodman B1370190 210°/180° Primary Limit Switch . He checked the blower capacitor, the air filter, the wiring and the flame sensor current. Part 307752. Over 20 years of experience, NATE DTAIR 31091 Limit Switch Replacement for Atwood/Hydro Flame/Dometic RV Furnace Heater 190℉ Goodman B1370195 300°/270° Primary Limit Switch Goodman B1370190 210°/180° Primary Limit Switch This Goodman B1370188 Primary Limit Switch 170F is a genuine OEM repair part. I had a service tech out Friday, but we didn't have the codes (my wife shut off power before he arrived) and he'll come back I'm sure. 80 /Count) This 49L88 Limit Switch is a genuine replacement part for furnaces and is available now from Repair Clinic. FREE Returns . 98 $ 13. According to schematic diagram this should mean that I HAVE AN AMANA AIR COMMAND 90 MODEL GUC070B30B I'VE REPLACED THE PRIMARY ROLLOUT LIMIT SWITCH ,THE IGNITER AND THE. - My Lenox furnnce turns off by itself. The LEDs indicate it's a limit switch. Ask a Question. Light flashes 4 times (Open High Limit). Primary Limit Switch (L170-30F) $16. All of the information in this limit switch replacement video is applicable to the following brands: Lennox Tools needed: 1/4 inch socket Connect With Us! May 25, 2012 · OEM Amana/Goodman 1370914S 220F Primary Limit Switch For Use With Model Series: GMP150-5, GMPH120-5. Goodman-Amana B1370195 - 300°F Primary Limit Switch, B1370195- B1370195 is an official OEM 300°F Primary Limit Switch for Goodman-Amana HVAC equipment. Safety Control. I have reset the indoor (using switch on unit) and outdoor (using breaker panel) units. Buy Goodman 20162904 150°/110° Primary Limit Switch: Limit Switches - Amazon. Feb 18, 2021 · Recent ice storm caused a power surge which resulted in a furnace no start when power was restored. Quality. Goodman-Amana B1370190 - Primary Limit Switch, B1370190- B1370190 is an official OEM Primary Limit Switch for Goodman-Amana HVAC equipment. Oct 19, 2020 · – Limit switches are electromechanical devices operated by a physical force applied to it by an object. The furnace makes a loud humming. Johnstone Supply is a leading wholesale distributor for HVACR equipment, parts and supplies available and in-stock at local branches. 5 4. 5 kg: Dimensions: 30 × 23 × 13 cm: Reviews There are no reviews yet. 0 5. Free shipping on orders over $99 Your Zip: 23917 Goodman B1370194 250°/220° Primary Limit Switch . Otherwise, you’d be exposing yourself to a significant danger. $18. Free shipping on orders over $99 Your Zip: 23917 Buy Goodman 20162904 Primary Limit Switch from our wide selection of Fan & Limit Controls. All of our parts are shipped factory direct, giving you the assurance you need for a quality repair on your furnace, air conditioner, or other Goodman product. Only 1 left in stock - order soon. These include: Always test the operation of the primary upper limit switch for the hoisting motion before each shift. I tried the a/c and got a different fault, called OU low pressure switch lockout. 3 out of 5 stars 102 1 offer from $1399 $ 13 99 Goodman-Amana 20162903SP - Limit Switch, 20162903SP- 20162903SP is an official OEM Limit Switch for Goodman-Amana HVAC equipment. 1 star 2 stars 3 stars 4 stars This Goodman 20162904 Primary Limit Temperature Control is a genuine OEM repair part. When the flame is not properly drawn into the heat exchanger, the rollout limit switch gets activated. 09 each Estimated to ship by 01/20 if ordered before 4:30 PM EST. Only 7 left in stock - order soon. Customer: i have a Lennox furnace, it says Primary/Secondary Limit Switch . Regan Land. $50. OEM Sep 27, 2013 · 02535381000 Furnace Temperature Limit Switch for York Coleman, Replace 02535381000 S1-02535381000 212439 60T11, Furnace Limit Switch L145-30F, Show Only Items Ordered Previously Got home this morning after 15 hour drive home after flight cancellation and house 46 degrees inside. Main blowers stays on the whole time. Save up to 15% with business pricing May 24, 2013 · Goodman 20162904 150°/110° Primary Limit Switch. Out Of Stock. The most common reasons for replacing the switch are when the furnace overheats or fails to heat. DuWayne. Free shipping on orders over $99 This Goodman 20162907 Primary Limit Switch - Orange is a genuine OEM repair part. 30. SKU: Furnace Limit Switch HH12ZB250 3" Upgraded for Carrier, Bryant, Payne, Day & Night L250, Auto High Limit Switch for Furnace Fan Replaces 1NT23L-3651 50+ bought in past month $16. 6. If your gas furnace is not heating properly, the problem may be a faulty limit switch. $7. Ensures HVAC system safety Regulates temperature limits Reliable and efficient Product HighlightsPrimary Goodman-Amana 10728335 - Primary Limit Switch, 10728335- 10728335 is an official OEM Primary Limit Switch for Goodman-Amana HVAC equipment. When the limit switch is dirty, it will have trouble working properly, causing your furnace to trip out excessively. Is this normal? I get continuity on the primary limit switch as well. Unlike the primary limit switch This Goodman B1370189 Primary Limit Switch 200F is a genuine OEM repair part. Before it enters Watchguard mode it gives a 3-1 Red flash code (Primary/Secondary limit switch open) Contractor's Assistant: How long has this been going on with your Lennox furnace? What have you tried so far? Nov 18, 2022 · Location of the high limit switch on a residential gas furnace High limit switch location inside of a furnace How to clean or replace a furnace high limit switch. This part 20162904 is L160-45F Limit Switch, 0200-194-001P. This Goodman B1370187 Primary Limit Switch 160F is a genuine OEM repair part. com Mar 14, 2015 · Limit Switch L350 Replacement, 47-22861-01 Furnace Limit Switch Srl350 350f, Compatible with Automobile Motor, Transformer, General Electrical Equipment Supplies(4 Piece) 4. The secondary limit switch is designed to provide an additional layer of safety and will usually shut off the power to the blower motor. Limit Switch - Primary L210°F -30°F (TOD #60T81-314371) Description: Primary Limit Switch, 210F; This Goodman B1370198 Primary Limit Switch 150F is a genuine OEM repair part. Free shipping on orders over $99 Lennox 27K79 Primary Limit Control Switch. Single Pole, Single Throw. 14 $ 13. Get it I really needed to replace the limit switches with some rated at 200 degrees and these are rated Find OEM Goodman 20162903 Limit Switch, Auto Reset, 160F replacement part at Parts Town with fast same day shipping on all in-stock orders until 9pm ET. The limit switch also controls when the blower assembly turns on and off. I think because the faults are so different, it's something else. 47 $ 7. Looks like high limit filter switch issue. Sep 25, 2018 · Genuine Original Equipment Manufacturer (OEM) parts! This primary thermal limit switch (part number 1370914S) is for furnaces. Unlike the primary limit switch, this has to be reset manually for the furnace to resume operations. Jan 5, 2024 · I also tested the control board and found 120VAC at 'Heat' contact (as expected). And I’ve bypassed the primary switch to. Goodman Amana Limit Switches Goodman Furnace Primary Limit Switch. Remember that you can also replace the limit switch. 98. Burner roll-out limit switch B1370145 detects when the flame flares out the front of the burner box and shuts down the burner to prevent overheating. In this video, we'll guide you through everything you need to know abo Limit Switch - Primary L150°F -30°F (TOD #60T81-314482) Description: Primary Limit Switch, 150F; I'm getting a primary limit switch open on my Lennex furnace. Dec 10, 2014 · The primary/auxiliary limit switches are self re-setting. 0 out of 5 stars. The most common reasons for replacing the switch are Dec 31, 2024 · Primary Limit Switch, B1370190. This part is compatible with the following models (Whichever is applicable. com FREE DELIVERY possible on eligible purchases Aug 19, 2010 · Honkador Updated 02535381000 Furnace Temperature Limit Switch, for York Coleman, Replace 02535381000 S1-02535381000 212439 60T11, Furnace Limit Switch L145-30F, Coleman Furnace Limit Switch 5. Goodman-Amana 0130F00038S - Auto Limit Switch (120F - 130F), 0130F00038S- 0130F00038S is an official OEM Auto Limit Switch (120F - 130F) for Goodman-Amana HVAC equipment. Trust Technical Hot & Cold for the right OEM replacement part. Availability : In Stock Pre order Buy GOODMAN B1370192 Limit Switch 230 Degree/200 Degree Primary-594498: Limit Switches - Amazon. Bard 8402-146 - Primary Limit Switch L185, 8402-146- 8402-146 is is an official OEM Primary Limit Switch L185 for Bard HVAC equipment. 0 out of 5 stars 1 rating. Goodman-Amana 10728325 - Primary Limit Switch, 10728325- 10728325 is an official OEM Primary Limit Switch for Goodman-Amana HVAC equipment. The limit guards against the overheating resulting from insufficient air passing over the heat exchanger When trying to turn on heat on my Lennox SL280UH070V36A-03, I get a fault called GF primary limit switch open. 37 Quantity. OEM Amana/Goodman B1370187 L160-30F Limit Switch For Use With Model Series: GMT135-5, GMT140-5, GMNT060-3 Jan 22, 2022 · The primary purpose of the limit switch is to make sure the furnace kicks on as soon as temperatures drop below a predetermined setting. Sep 14, 2021 · Primary Limit Switch: This limit switch prevents the furnace from reaching super high temperatures that can be dangerous. I'm looking at the limit switch 84L001 and can't see an. Rick. For Goodman. We recently replaced the primary limit switch. 29,729 Satisfied Customers. Free shipping on orders over $99 Your Zip: 23917 Jun 15, 2022 · In addition to these requirements, several best practices are recommended for crane or hoist operators and owners to ensure the functionality and safe use of hoists’ upper limit switches. The squirrel cage turns freely. 14. The early limit switches were used in systems to define or reduce the limit of travel of an object. SKU: B1370188. Free shipping on orders over $99 Your Zip: 23917 This Goodman 0130F00035 Primary Limit Switch - Purple is a genuine OEM repair part. The limit switch is a safety switch that monitors t Goodman-Amana B1370194 - 250°F Primary Limit Switch, B1370194- B1370194 is an official OEM 250°F Primary Limit Switch for Goodman-Amana HVAC equipment. Next I plan to pull the blower out to see if there is something clogged or dirty there. Both pressure switches seem to be working, but I have noticed with the pressure switch on the right (ID blower switch) I get continuity between the two wires connecting it. Carrier Factory Trained. It's kind of pointless on your furnace. Free shipping on orders over $99 Your Zip: 23917 Oct 15, 2011 · The primary limit switch, which prevents the furnace from heating to unsafe temperatures, is programmed to reset automatically after a malfunction. Pressure Switch (1) Primary Limit Temperature Control (1) PVC Termination Screen (2) Goodman 20162905 Primary Limit Switch, 145 – 40F. It is brand new in the original Goodman factory packaging. This switch opens at 180°F and closes at 210°F. com FREE DELIVERY possible on eligible purchases This Goodman 20162906 M4 Primary Limit Switch is a genuine OEM repair part. As soon as they cool off to the temperature shown on the label they will close and show continuity. Return this item for free. The primary limit switch is the one that is most likely to trip first, and it will usually shut off the gas flow to the burner. Your Account Primary auto limit switch. I've changed out the filters and taken off the squirrel cage fan on the front and shook out some dust but it wasn't what I'd consider dirty (looked like a dirt-dobber next fell in from the exhaust pipe). Free shipping on orders over $99 Your Zip: 23917 Apr 27, 2022 · When the limit switch senses that the plenum air supply has reached its lower temperature setting, the limit switch shuts off the blower fan so cool air won’t circulate through the ducts. Brand : Empire Comfort Systems : Mounting Type : Floor Mount : AZ4U Flame Rollout Switch 2Pack 47-22861-01 Limit Switch Replaces 47-100241-01 for Rheem Furnace Limit Switch L350 SRL350 350F B13701-88 - Goodman OEM Furnace Replacement Limit Switch L170-30 Goodman B1370198 Furnace Temperature Limit Switch Genuine Original Equipment Manufacturer OEM Part Auxiliary Limit Auto Reset Switch (1) Auxiliary Limit Switch (3) HIgh Limit Switch (1) Limit Control (1) Limit Switch (13) Manual Reset Limit Switch (12) Primary Limit Switch (19) Primary Limit Temperature Control (1) Reset Limit Switch (1) Rollout limit switch. Empire Primary Limit Switch R1821 for Empire Floor Furnaces 3588-2, 5088-2, 7088-2 Free Shipping applies to orders over $99 within the contiguous 48 US States. 95 / ea. Primary Limit switch is open. The Goodman Primary Limit Switch 20162904S is meant to be compatible with Goodman and Amana products. Goodman B1370189 Furnace Primary Thermal Limit Switch Genuine Original Equipment Manufacturer (OEM) Part. You must identify your local store and sign in to see local price and availability information and place orders. Normally Open Replaces 27K7901. Aug 16, 2023 · The primary limit switch is an important safety component that prevents overheating. Oct 21, 2015 · Goodman Primary Limit Switch, Light Blue. 29,533 Satisfied Customers. The pressure switch is open when flue motor not running - as expected. 47. 20 years experience with installation and service of residential/ light commercial HVAC equipment. com FREE DELIVERY possible on eligible purchases The primary limit switch is a temperature-activated sensor that protects your furnace from overheating whenever the fan fails to blow enough air over the heat exchanger. If I reset it, it works for some time (30 min ~ couple of hours) and then goes off. 10728330 is an official OEM Primary Limit Switch for Goodman-Amana HVAC equipment. 36 $ 18. + This Goodman 20162901 Primary Limit Switch is a genuine OEM repair part. Rollout Limit Switch: This limit switch is activated only when the burner flames are not adequately drawn into the heat exchanger. No heat. Buy GOODMAN 10123535 Limit Switch Blower, 150 Degree Manual Reset-594486: Limit Switches - Amazon. 0 out of 5 stars 4 1 offer from $2683 $ 26 83 Limit Switch - Primary 300°F - 30 Differential (TOD 60T81-314376) Description: Primary Limit Switch, 300F; Order #: L40-223. The primary limit when cold is closed, so seems to work. : 764. The limit switch in a furnace senses the temperature of the furnace and communicates to the blower fan to turn on and off at the appropriate times. , Pink (0130F00036SP) GOODMAN Capacitor, 10 MFD, 370V, Oval (100000440LA) GOODMAN Sensor Thermistor, . Home Goodman 0130f00036sp. My furnace will run between a few hours to a few days but eventually, it'll stop working. 49 $ 14. Open Expanded View . The primary limit switch is located on the partition panel and monitors heat exchanger compartment temperatures. 1-800-269-2609 24/7. Goodman HVAC System Primary Limit Switch (L170-30F) - B1370188 | HVACDirect. 88 ( $168. The high limit switch in a furnace can sometimes get dirty. Free shipping on orders over $99 I have a Lennox G40UH-36C-110. Diagnostic light #1 is flashing while #2 is on. Please see below for important warranty information and a list of models that this part fits. Internal Product ID: Catalog Pg. Nothing obvious. Brand Goodman. com FREE DELIVERY possible on eligible purchases Buy Goodman 20162904 Primary Limit Switch from our wide selection of Fan & Limit Controls. 5 out of 5 stars Aug 17, 2015 · This video provides step-by-step instructions for replacing the safety limit switch on Lennox furnaces. Your price: $5. May 24, 2013 · Buy Goodman 20162907 Goodman Limit Switch Primary Twidec/10Pcs Mini Micro Limit Switch 5A 125 250V AC SPDT 1NO 1NC Very Long Straight Hinge Lever Arm Switch Snap Find OEM Goodman 0130F00036 Limit Switch, Primary, Pink, 180°F replacement part at Parts Town with fast same day shipping on all in-stock orders until 9pm ET. ohiuhc bzf qslnqv zyvrl ncligt lwjx iiwlcmw wnc gdmxdo prqew