Brocade fcip tunnel commands. Displays information for a single specified FCIP tunnel.


  • Brocade fcip tunnel commands Before proceeding, make sure you have: Two Brocade switches (or a FCIP. Search. Fcipentityinstancetable. • Hybrid mode only. x 9. Management of the tunnels can often involve monitoring the FCIP traffic across the WAN, as well as monitoring the associated FC traffic and each end of the tunnel - SANnav provides ample tools for the monitoring of both types of traffic. commands using the Fabric OSCLI. As you plan the tunnel configurations, be aware that uncommitted rate tunnels use a minimum of 1000 Kbps, up to a maximum of available uncommitted bandwidth on the GbE port. Switch Ports. On the Brocade 7810 or SX6, specify the . 0 FCIP tunnels are typically established across Wide Area Networks (WANs). Iscsi MIB Overview. Use this command to configure FCIP tunnels and FCIP circuits on the Brocade 7810 switch and Brocade SX6 extension blades only. 2018/03/09-07:41:06, [ESM-2104], 146081, FID 128, INFO, 7840_FCIP_2, VE Tunnel 24 is OFFLINE. 2: Packets: Sent = 4, Received = 4, Loss = 0 ( 0 percent loss) RTT = 0ms, Max RTT = 0ms Average = 0ms If you are able to ping, then The Fabric OS command line interface (CLI), accessed via Telnet, SSH, or a serial console, provides full management capability on SSH, or a serial console, provides full management capability on a Brocade switch. 1x or later, and the Brocade Fabric OS Command Reference Manual, version 8. Set both Brocade 7840 switches to hybrid mode, and verify the mode change. x; Fabric OS Commands; aptPolicy; Brocade® Fabric OS® Command Reference Manual, 9. Table of Contents. Page 14 Managing FCIP tunnels. 1095. Fabric OS FCIP Administrator’s Guide iii 53-1002474-01 Document History Title Publication number Summary of changes Date Fabric OS FCIP Administrator’s Guide 53-1001349-01 New document. The Brocade 7810 base configuration provides four 32Gb/s-capable Fibre Channel ports and six 1/10GbE ports with Adaptive Rate Limiting (ARL) and IPsec. e. Define an IP interface on each virtual GigE port. option. 0 (53-1000436-01, june 2007) (816 pages) Page 92 FCIP tunnel issues Reply from 11. Certain switches in the MetroCluster FC switch fabric support encryption or compression, and sometimes support both. 40. 1 FOS-821-Ext-UG101 28 September 2018 • Brocade DCX 8510-4 Backbone and Brocade DCX 8510-8 Backbone with one or more Brocade FX8-24 Extension Blades • Brocade 7840 Extension Switch • Brocade X6-4 Director and Brocade X6-8 Director with one or more Brocade SX6 Extension Blades The following software is supported as described in this configuration guide: • Brocade Fabric OS 8. FCIP You might need to rename a Brocade FC switch to ensure consistent naming throughout your configuration. 305 Modifying FCIP tunnels . 305 Viewing FCIP tunnel Information. If VE_ports on Supporting Fabric OS 8. 100. The Brocade SX6 Blade DP cannot be configured in FIPS mode, which Hybrid mode does not support. Verify the I'm trying to get FCIP set up between an IBM 18B-6 and a Brocade 7840. FCIP Extended Link Table. 5Gb/s to allow for scalable connectivity between sites. This operand is optional and valid only with the . FCIP Tunnel Management. 0 or above and on Gen 7 directors from Fabric OS 9. The same Brocade Fabric OS® version is required on both ends of a tunnel. Learn concepts, features, configuration procedures, troubleshooting tips and more. When you reboot a switch connected to a fabric, all traffic to and from that switch stops. portStatsShow Specifies a tunnel ID to display statistics only for the specified FCIP tunnel. 3 and later, an FCIP tunnel is created with multiple FCIP circuits over different IP interfaces to provide WAN load balancing and failover recovery in the event of a limited WAN outage. Brocade Fabric OS Extension User Guide. (Powerlink -> Support -> Technical Docu -> Hardware -> Connectrix) We have three 7500 for fcip use by ipsec with compression, fast write and tape pipelining enabled. Configuring tunnels for Fabric OS Commands for Configuring SNMP. Logging. command traces routes from a local Ethernet port to a destination IP address. 78 255. On the Brocade 7810 Extension Switch and the Brocade SX6 Extension Blade, because DP complexes share Ethernet ports, identification for the port is Confirm that the IP configuration is correct on both tunnel endpoints using the following commands. This operation may be disruptive, and the command prompts for confirmation before executing. Yes. Extension. Displays information for a single specified FCIP tunnel. Virtual Fabrics and the Brocade 7800 command to disable the port on which you want to configure encryption. Fabric OS MIB Reference. EX-Port – A connection that connects 2 fabrics together without merging services The 'local-backup' tunnel is viewed as the 'remote-backup' tunnel on the remote switch because of symmetric configuration. x. a VE_Port in a Brocade SX6 Extension Blade. 0, including basic configuration tasks, advanced configuration, managing user accounts, security protocols, and Virtual Fabrics. 0 (53-1002753-01, March 2013). ge0 cu 1G Offline FCIP Copper Disabled (Unsupported blade mode) ge1 cu 1G Offline VE-Port – FCIP interconnected E-Port/ISL, i. command to enable the port. 2 Configure FC fastwrite feature fciphelp Print FCIP help info fcipledtest Cycle user port LEDs. Broadcom FOS-82x-Command-RM110 13 Reference Manual Brocade® Fabric OS® Command Reference Manual, 8. Errors in RAS log: [XTUN-1008], 296232, CHASSIS, WARNING, MP_7800B, FCIP Control block memory usage slot=0 DP=1 Allocated=57308032 Free=144018560 Total=201326592. 2: bytes=64 rtt=0ms ttl=64 Ping Statistics for 11. command Commands are printed in bold. Top; Brocade Fabric OS CLI Commands. Understanding Role-Based Access Control. Brocade Fabric OS CLI Commands. This mode enables FCIP and IP Extension traffic to traverse through the tunnels. Also for: FOS-821-SW-Lic-UG104 User Guide Brocade® Fabric OS® Software Licensing User Guide, 8. In the case of the Brocade SX6 and Brocade 7850, the 40GbE and 100GbE interfaces do not support LAN side (IP Extension) operation. Fabric OS Commands for Configuring SNMP. Corporate Site. FCSwitch1:admin> cfgadd "cfg_name", "ZONE2" 6. StoreFabric SN6500B storage pdf manual download. Notice to the Reader. -argument, arg Arguments. 1 USER GUIDE Brocade Fabric OS Extension User Guide, 8. Using Fabric OS Commands. Brocade FCIP uses high-efficiency encapsulation to encapsulate Fibre Channel into TCP/IP for transport over a long-distance WAN from anywhere, to anywhere—across the state and around the globe. Brocade® Fabric OS® Administration Guide, 9. PDF. Gen 6 Directors. x software PDF manual download and more Broadcom online manuals. FCIP mode allows you to chose between 10VE mode and 20VE port FCIP tunnel restrictions for FCP and FICON See “Brocade resources” on page xii for instructions on accessing Brocade Connect. OFF. You can define multiple policies, but only one policy can be applied to each tunnel. Any commands not listed in this command reference are not supported and may be subject to removal without notification. Others behave differently depending on the platform on which they are executed. 15 on a Brocade 7810 Switch. 4. The details in this document are specific to the configuration of IP Extension on the Brocade 7810 Extension Switch (image FCIP tunnels flapping on Brocade 7800 or Director with FX8-24 Extension Blade. Time. In the 7. The command syntax is as follows: portCfg fciptunnel On the Brocade 7840 switch, before enabling IPsec on a tunnel, you must first define an IPsec policy using the portcfg ipsec-policy command. The Brocade X6 family supports 4, 8, 10, 16, and 32 Gbps Fibre Channel, FICON, and 1/10/40 Gbps Fibre Channel over IP (FCIP) via two blade options, the Brocade FC32-48 Fibre Channel Blade and the Brocade SX6 Extension Blade. 1x or later. – The switch does not support FCIP connectivity to the Brocade 7800 or FX8-24 blade because connections to these products are inoperable. Determining DATA CENTER Brocade Switch Cookbook 8 of 197 Deleting port groups . The Fabric OS command line interface (CLI), accessed via Telnet, SSH, or a serial console, provides full management capability on a Brocade switch. Output may vary depending on the switch model. Check whether the FCIP license is applied. x; Fabric OS Commands; portStatsShow; Brocade® Fabric OS® Command Reference Manual, 9. Also for: Poweredge m1000e, 8/80, Poweredge m600, Poweredge m605, Poweredge m610, Poweredge m610x, Poweredge m710, Poweredge m710hd, Poweredge m805, and the Brocade SX6 Extension Blade are the newest members of the Brocade Extension product family and the latest generation of Brocade products for FICON extension beyond traditional distance limitations, providing FICON Inter-Switch Link (ISL) extension over a Fibre Channel over Internet Protocol (FCIP) connection. Displays supported on the Brocade 7810 switch and Brocade SX6 blades. The logical switches and the FCIP tunnel in those logical switches will provide a determinant path for all FICON sequences between the host and device ports in that logical switch pair. 0 (53-1002748-01, March 2013) Brand: Brocade Communications Systems FCIP Tunnel Restrictions for Use this command to display switch, blade, and port status information. Brocade DCX 8510-8 with the following blades: • Brocade FC16-32 Port Blade • Brocade FC16-48 Port Blade • Brocade FC16-64 Port Blade • Brocade FX8-24 Extension Blade • Brocade FCOE10-24 Blade 8. Displays port configuration settings. Brocade® Fabric OS® Web Tools User Guide, 9. Multiple circuits can be configured as a trunk, which provides multiple source and destination addresses to route traffic across an IP network, provide load leveling, and provide failover capabilities. Gen 7 Directors. N/A. SupportShow. Modifying an FCIP tunnel Modifying an FCIP tunnel FCIP tunnel characteristics and options can be modified as needed, using the portCfg fcipTunnel command with the modify option. ; 7840 EAST and WEST extncfg hybrid; Verify mode change: extncfg --show 2. In Fabric OS v6. 2 REST API with New RESTCONF Modules FOS 8. 11. The tunnel statistics section provides information such as FCIP aggregate, FCIP QoS, and FCIP TCP statistics of the selected VE port. ipif. Use the . This procedure must be This guide provides information on the configuration and management of Brocade Fibre Channel over IP (FCIP) tunnels, which allow you to extend your Fibre Channel storage area network Modifying an FCIP tunnel Modifying an FCIP tunnel FCIP tunnel characteristics and options can be modified as needed, using the portCfg fcipTunnel command with the modify option. 43. 1. 9999 percent uptime in the world’s most demanding data This command is disruptive and requires rebooting the switch. -params Connection parameter information. • Brocade extension switches and blades use FCIP trunking features to overcome the limitation of one Ethernet interface, one IP address, and one FCIP tunnel. the backslash. This solution is very The FCIP extended link table contains statistical information about FCIP tunnel transport operation. With Brocade Gen 6 Fibre Channel, IP extension capability, and Brocade Fabric Vision Brocade Communications Systems 53-1001763-02 FCIP tunnel configuration . IP Extension Flow Monitor overview. [ ] Optional element. By default, the configured tunnel is enabled to run FCIP mode. For normal extension tunnel operations over tunnels transporting FICON traffic, the KATOV for all circuit members of a VE_Port (tunnel) must be less than the overall I/O timeout for all FC exchanges. Use the following section headings to navigate this page. command to display FCIP tunnel and circuit parameters. Specifies a tunnel ID to display statistics only for the specified FCIP tunnel. This table gives FCIP circuit statistics for the Brocade 7850 Extension Switch or the SX6 Extension Blade. is set to . Brocade® Fabric OS® Command Reference Manual, v9. The switch must be disabled before you configure switch parameters. When using the 10 Gbps VE ports (which use FCIP) for ISLs, you must create IP interfaces on each port, and configure FCIP tunnels and circuits in each tunnel. This manual documents all officially supported Fabric OS commands. Assigning backbone fabric IDs, FCIP tunnel configuration The Brocade 7810 Extension Switch supports the following functions: • Four logical Extension tunnels with combined maximum bandwidth of 2. In summary, the "portshow fciptunnel -c --lifetime" command provides cumulative statistics for the lifetime of the tunnel, while the "portshow fciptunnel -c uptime" The second phase involves logging in to the Brocade Extension device and issuing commands that configure the features available on that device. ge0 cu 1G Offline FCIP Copper Disabled (Unsupported blade mode) ge1 cu 1G Offline This document provides a comprehensive guide to configuring and managing Brocade's Fabric OS v7. Additional Information. 1/10GbE interfaces to provide high-bandwidth Extension tunnel and lossless failover resiliency. 1123. Feature . FC Compress Mode. Use . Optional Args: -perf Additional performance information. Brocade 8/12c software pdf manual download. (Brocade X6-4 Director or Brocade X6-8 Director) with two CPs Fibre Channel and advanced FCIP technology, the Brocade 7800 provides a flexible and extensible handling of initiator-target flows within the same FCIP tunnel for transmission Web Tools, and the command line interface. You can display the entire lifetime of statistics for the tunnel using the following command. This command creates a tunnel with a single circuit. 0 (53-1002748-01, March 2013) Brand: Brocade Communications Systems FCIP Tunnel Restrictions for These messages indicate the status of FCIP tunnels, FCIP emulation events for FCP traffic, or FCIP debug information (FTRACE buffer status changes). 0 Brocade X6-4 and Brocade X6-8 with the following blades: • Brocade SX6 Extension Blade • Brocade FC32-48 Port Blade • Brocade FC32 command to trigger a sync of the actual firmware from the active CP to the standby CP. IPv6 addresses are supported. and a set of examples. 1 (interface GigabitEthernet4/1) Listen Port is 3225 TCP parameters SACK is enabled PMTU Configure the Brocade SX6 Blade to operate in Hybrid mode, which supports FCIP tunnel features and IP Extension features. Using the portshow You must use this command in a manner that honors the platform-specific differences in command syntax and behavior. By default, the VE_Port is persistently enabled. In addition, each circuit supports the following QoS classes as Use this command to display switch, blade, and port status information. Configuring the switch for FICON is a disruptive process. Displays information for the specified FCIP tunnel. two lines of a command input, enter the entire command at the prompt without. View and Download Brocade Communications Systems 8 reference manual online. 25. Enable persistently disabled ports. View online or download Brocade communications systems PowerEdge M600 Release Note We have 11 Brocade Communications Systems PowerEdge M600 manuals available for free PDF download: Command Reference Manual, Reference, Administrator's Manual, Tunnel and TCP Graph Command Line Interface (CLI): SSHv2 or Telnet, Web Tools: HTTP/HTTPS, SNMPv1/v3 (FE MIB, FC Management MIB), SMI-S, RADIUS, LDAP SSH v2, HTTP/HTTPS, SNMP v1/v3, Telnet; SNMP (FE MIB, FC Management MIB); Brocade Web Tools; Brocade SANnav Management Portal and SANnav Global View; Command Line Interface (CLI); LDAP Security. x License Types Fabric OS supports the following license types: • Permanent license – A permanent license enables a license-controlled feature to run on the switch indefinitely. The time basis for the statistics will display in the output. 0. The Brocade 7810 Extension Switch operates solely in Hybrid mode. VE_Port number This administration guide provides information on configuring and managing Brocade Fibre Channel over IP (FCIP) tunnels. Before enabling IPsec on a tunnel on the Brocade 7810 Switch or the Brocade SX6 Blade, you must first define an IPsec policy. fcoe Displays and configures FCoE ports FIP and fcmap configurations fcoelogincfg Enable/Disable Save or display FCoE login TDMs, FCR (native FC Routing), or FCIP extensions are not supported for the MetroCluster FC switch fabric. 13. 3. 12. 6. The purpose here is to create a FCIP tunnel between these Brocade 7840 switches situated at Brocade communications systems PowerEdge M600 Pdf User Manuals. An Extension tunnel between a Brocade 7810 Extension Switch and Brocade SX6 Extension Blade is interoperable. • Brocade DCX 8510-4 Backbone and Brocade DCX 8510-8 Backbone with one or more Brocade FX8-24 Extension Blades • Brocade 7840 Extension Switch • Brocade X6-4 Director and Brocade X6-8 Director with one or more Brocade SX6 Extension Blades The following software is supported as described in this configuration guide: • Brocade Fabric OS 8. By default, the Brocade 7840 is in FCIP mode and does not support IPEX. command. July 2009 Brocade® Fabric OS® Command Reference Manual, 9. July 2009 Fabric OS Troubleshooting and Diagnostics Guide Brocade Communications Systems, Inc. Flow generator generates FC frames for a defined flow with default or custom size and pattern and sent across FCIP tunnel to help validate end-to-end network setup and configuration. Creating an FCIP tunnel Creating an FCIP tunnel After you have verified licensing and connectivity between source and destination IP interfaces, you can configure FCIP tunnels. 2. The command syntax is as follows: portCfg fciptunnel ve_port modify <options> Where: ve_port Each tunnel is assigned to a specific VE_Port. 1588. 8 software pdf manual download. 2 and details the most common configuration tasks needed to replace a Brocade 7800 with a Brocade 7810. The Brocade Virtual Brocade® Fabric OS® Extension User Guide, 8. --option, option Command options are printed in bold. 1 and above or the Brocade 7810, Brocade 7850, and Brocade SX6 on Brocade FOS 9. Gen 7 Extension Switches. switch:admin> extncfg --app-mode fcip. To display the tunnel, specify the VE_Port number associated with the tunnel configured on one of But this "disrupts the traffic on the specified FCIP tunnel for a brief period of time". Verify that the switches have been set up according to the instructions in Configuring FICON. The pre-shared key must be 16 through 64 characters long. On unsupported platforms, the command displays a "not applicable to this platform" message next to the FCIP command group. portcfgencrypt --enable. 1 About This Document This Brocade Fabric OS Command Reference Manual details the commands that can be issued on devices that support Fabric OS® 8. N/A . 0 Brocade FC32-48 Port Blade 8. On the Brocade 7810 or 7850 or SX6, specify the VE_Port number associated with the tunnel configured on one dialog for an FCIP tunnel on a Brocade 7840 Switch, the Brocade 7850 Switch, or Brocade SX6 Blade. Enter the . 1. Page 71: Deleting An Ip The Brocade 7810 Extension Switch, Brocade 7850 Extension Switch, and Brocade SX6 Extension Blade are compatible. The same information can be accessed by issuing the help command followed by the command name on a Brocade switch or director. -ipsec IKE and IPSec policy information on IPSec enabled tunnels. In FCIP mode, each DP allows up to 20G of FC traffic (up to 40G with 2:1 compression). 0 (53-1000436-01, june 2007) (816 pages) or 256 ports with device and Brocade UltraScale ICL ports. 4. 14. 168. Moreover, optional FICON Control Unit Port (CUP) capabilities enable legacy management applications to seamlessly Brocade communications systems Fabric OS FCIP Pdf User Manuals. Brocade has developed an optimized TCP stack, called Storage Optimized TCP (SO-TCP), specifically for use with storage. connections, updated commands, removed obsolete information, and moved the FCIP and FICON chapters into their respective books. 146080, FID 128, INFO, 7840_FCIP_2, VE Tunnel 24 is DEGRADED. 137 Brocade® Fabric OS® Extension User Guide, 9. Key Terms. Use this command to perform a "cold reboot" (power off/restart) of the control processor. You can configure the following switch modes: ∙. x frames, out frames, words received, and words transmitted. 1 expands REST API support from that supported in FOS 8. Gen 7 Defining a compound set of CLI filters for use with extension commands . X6-4/X6-8 Director, if an SX6 blade is present: (AP) blades may be affected. Issuing either a switch disable or an FCIP Tunnel disable command allows the FCIP FICON Emulation processing state-machine to execute an orderly cleanup process and allow normal activation of the new configuration. The When using the 10 Gbps VE ports (which use FCIP) for ISLs, you must create IP interfaces on each port, and configure FCIP tunnels and circuits in each tunnel. 8. Persistently disable the VE_Port before you begin configuring the tunnel on the VE_Port. n The following Brocade 7810 Ethernet interfaces The four supported Brocade switches must be connected to two fabrics of two switches each, with each fabric spanning both sites. The FCIP commands are supported only on the Brocade 7810 switch and Brocade SX6 blade. FCSwitch1:admin> cfgcreate "new_cfg", "ZONE1" To add a zone to an existing config, run the cfgadd command. 0 Directors Brocade X7-4 and X7-8 with the following blades: • Brocade FC64-48 Port Blade • Brocade FC32-X7-48 Step-by-Step FCIP Configuration on Brocade Switches 1. Commands. ZONE Zone module messages indicate problems associated with the zoning features, including commands associated with aliases, zones, and configurations. However, if you want to enable the configured tunnel in Hybrid mode, thereby running both FC and IP traffic, you must check . Verify that the FCIP tunnel has been successfully created: portshow fciptunnel all. Version. I am herewith attaching the "show run" command of one of the Nexus 5548UP along with this. Brocade Fabric OS FCIP Administrator's Guide v7. By comparing the command output at each end of the tunnel, you can usually identify Modifying an FCIP tunnel Modifying an FCIP tunnel FCIP tunnel characteristics and options can be modified as needed, using the portCfg fcipTunnel command with the modify option. Displays which GbE port is currently active in the Brocade 7810 Switch. Fciplinktable. View All. The FCIP tunnels on the local and remote ports act as Virtual E_Ports (VE_Ports) connecting the local and remote fabrics. (TCP port 3225, and for the Brocade 7810 Switch, and Brocade SX6 Blade, TCP port 3226) and IPsec traffic if IPsec is used (UDP port 500). 0 (53-1002748-01, March 2013) Brand: Brocade Communications Systems FCIP Tunnel Restrictions for Configure the Brocade SX6 Blade to operate in Hybrid mode, which supports FCIP tunnel features and IP Extension features. Open/Close Topics Navigation. A GE interface cannot operate in both LAN and WAN modes. x Chapter 1: Introduction 1. Use the switchShow command for a list of valid ports. 0 (53-1001764-01, march 2010) (1080 pages) “ISL Trunking Issues” Buffer credits FCIP tunnel Fibre Channel over IP Administrator’s Guide LEDs are flashing Links Chapter 3, “Connectivity Issues” With twelve 32 Gb/s-capable Fibre Channel ports, six 1/10-Gigabit Ethernet (GbE) ports, and a 2. portCfgShow. This option is supported on Brocade SX6 extension blade. switch:admin> portdisable 7/24 switch:admin> Brocade fabric os command reference manual - supporting fabric os v5. • FCIP tunnel bandwidth has a minimum rate of 1544 Kbps (T1 rate). switch:admin> firmwaredownload Server Name Fabric OS Commands for Configuring SNMP. If there is an active FCIP tunnel on the SX6 Extension blade, the FCIP tunnel traffic is impacted for at least 2 minutes. This operand is optional and valid To set the switch to FCIP mode, use the extncfg --app-mode fcip command. Brocade Network Advisor Documentation Updates v11. 0 Brocade fabric os command reference manual supporting fabric os v6. Notes, cautions, and warnings Each end of the FCIP communication path must be a compatible FCIP device, either the Brocade 7800 or the FX8-24 blade in a DCX-family chassis. Support for Administrative Domains. 255. Up to 10 IP interfaces and 10 FCIP circuits are supported on the 10GbE port. 3. Brocade Fabric OS Command Reference Manual. When there are multiple paths to a destination, the input traffic is distributed across the different Configuring LAG. 0 (53-1002748-01, March 2013) Brand: Brocade Communications Systems FCIP Tunnel Restrictions for Displaying FICON emulation configuration values • To create a empty tunnel as a FICON FCIP tunnel, use the following command: portcfg fciptunnel 1/17 create -F -c 1 • To modify a tunnel to be FICON enabled and with hardware compression enabled, use the following command: portcfg fciptunnel 1/17 modify -c 1 -F 1 Displaying FICON emulation configuration values For Brocade Fabric OS Commands for Configuring SNMP. The uptime statistics include the time since the tunnel was last reset, the time since the tunnel was last brought up, and the time since the tunnel was last taken down. 9. 0 or above when a Brocade SX6 Extension Blade has been installed. FCIP Interface: A logical interface that facilitates communication between Brocade switches over IP. The general tunnel and circuit requirements that apply to Brocade Extension platforms are as follows: You can define multiple addresses on Ethernet ports to configure multiple circuits. The general syntax of the . x code level from brocade there is a defect for an fcip tunnel that has compression 'aka deflate and/or fastdeflate configured on that can cause the fcip tunnel to fail. Keepalive timeouts seen in RAS log. 0 1500 Validating IP connectivity The -s option specifies the source address, and the Brocade G720 Switch 9. Can anyone please help to check the interoperability of Nexus 5548 and Brocade. Deleting an FCIP Circuit on a Brocade 7800 FX8-24 Blade. 2. We have 9 Brocade Communications Systems 6505 manuals available for free PDF download: Reference Manual, Command Reference Manual, Administrator's Manual, Hardware Installation Manual, Deleting an FCIP Tunnel on a Brocade 7800 FX8-24 Blade. To display the tunnel, specify the VE_Port number associated with the tunnel configured on one of the GbE ports. n The tunnel configuration comprises two circuits: VE12–Circuit0 and VE12–Circuit1. Basic FCIP Requirements FCIP Tunnel: A logical path that allows Fibre Channel frames to be encapsulated within IP packets. or . from the Task 1. ” Since a trunk is logically a single tunnel, only a single VE or VEX_Port is used, regardless of the fact that more than one circuit may be contained within the To configure FCIP tunnels, perform the following steps: Interface 1. However, with Extension Trunking, each circuit is not its own tunnel, hence the term “circuit. 1108. command to define a policy. FCIP mode—In this mode, only FCIP traffic is sent over the extension tunnels. Gen 6 Extension Switches. When multiple FICON emulation FCIP tunnels are required between a pair of chassis, define a new logical switch pair (one logical switch in each chassis) for each tunnel. 0a with the following new features and corresponding RESTCONF modules: Physical chassis, FRU, and optical transceiver: brocade-chassis, brocade-fru, and brocade-media Switch configuration: brocade-fibrechannel-configuration SupportSave: To add a zone to a new config, run the cfgcreate command. Using the Command Line Interface. By default . Copper. portenable. admin> portshow fciptunnel --all -c Tunnel Circuit OpStatus Flags Uptime TxMBps RxMBps ConnCnt CommRt Met/G ----- 7/25 - Up Brocade SX6 Extension Blade: Delivering Business Resiliency At Scale The Brocade SX6 Extension Blade is a multiprotocol extension solution that securely moves more data over distance faster, while scaling to support the world’s most demanding environments. Brocade SX6 Extension blade. The command is used in IBM z/OS Global Mirror configurations to read updates from a volume in an active mirroring session. x User Guide • Brocade Fabric OS Command Reference , 9. ONTAP - Configuring 10 Gbps VE ports on Brocade FC 7840 switches Modifying an FCIP tunnel Modifying an FCIP tunnel FCIP tunnel characteristics and options can be modified as needed, using the portCfg fcipTunnel command with the modify option. switch:admin> portcfg ipif ge0 create 192. The optional Fibre Channel over IP (FCIP) Tunneling Service enables you to use tunnels to connect instances of Fibre Channel SANs over IP-based networks to transport all FC ISL and Brocade Fabric OS Command Reference Manual for a description of the command syntax and output. Displays the address resolution protocol (ARP) table. ICL, trunk group, or FCIP tunnel. x User Guide 19 April 2021 FOS-821-Ext-UG105 19 April 2021 Broadcom The Brocade SX6 Extension Blade can assume both modes, though the default is FCIP. After manually enabling the port, the new configuration becomes active. The Brocade Fabric OS Features and Standards Support Matrix provides a high-level, consolidated view of all features that are supported on Brocade® Fibre Channel platforms that run Fabric OS® 9. The command syntax is as follows: portCfg fciptunnel ve_port modify <options> Where: ve_port Each tunnel is assigned to a specific VE_port. If FICON emulation features (IBM z/OS Global Mirror or Tape Pipelining) are enabled on an FCIP tunnel in the switch, set either PBR (aptPolicy 1) or DBR (aptPolicy 2 Brocade® Fabric OS® Features and Standards Support Matrix, 9. This problem can show up with the fcip tunnel configured with deflate on and there is a real problem with the WAN link that the fcip tunnel is using. portShow Displays information for a single specified FCIP tunnel. The following operations can be performed with this command: This Brocade Fabric OS Command Reference Manual details the commands that can be issued on devices that support Fabric OS 9. 2 This table also gives details Fabric OS FCIP Administrator’s Guide iii 53-1002474-01 Document History Title Publication number Summary of changes Date Fabric OS FCIP Administrator’s Guide 53-1001349-01 New document. The main purpose of this tool is to determine the health of a link before deploying it for use as a circuit in a tunnel. 7840_FCIP_2:admin> reboot Warning: This command would cause the switch to View online or download PDF (5 MB) Broadcom Brocade Fabric OS Command Reference , 9. 1086. Verify IP connectivity. Admin; Site Tools. x firmware, documenting all possible configurations and scenarios is beyond and both FC and IP ports for FCIP. When defining the IPsec policy, use the -K An FCIP tunnel emulates FC ports on the extension switch or blade at each end of the tunnel. bison# sh fcip profile 1 FCIP Profile 1 Internet Address is 100. Some command options are not available on all platforms. Define IP routes on GigE ports. For further information look into your FOS command reference guide. Setup. x (53-1002363-03, August 2011). fabrics will merge; VEX-Port – FCIP interconnected EX-Port, routing needed via lsan zoning to connect initiator to a target. arp. portCmd --traceroute. 0 (53-1001186-01, april 2009) (894 pages) Switch Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Command Reference Manual. Configure the virtual GigE ports. Brocade® Fabric OS® Command Reference Manual, 9. Brocade SX6 1GbE/10GbE interfaces and Brocade 7850 1GbE/10GbE/25GbE interfaces are in groups, and the speed must be consistent within each group. Also if possible please suggest best practice to implement this solution. Displays the IP interface configurations. Save config. 0 Brocade FC32-64 Port Blade 8. 0 Brocade MXG610 Blade Server SAN I/O Module Embedded FOS Brocade X6-4 and X6-8 with the following blades: Brocade SX6 Extension Blade 8. On the Brocade 7800 and FX8-24, up to eight IP interfaces per GbE port are supported, but only 4 FCIP circuits can be configured on a single GbE port. CP blades These blades have a control processor (CP) used to control an entire Brocade X6 Director. net is command references/cheat sheets/examples for system engineers. Page 52: Deleting An Ip Route The Brocade 7840 base configuration is a comprehensive bundle that includes a set of advanced services: FCIP, IP extension, Brocade Fabric Vision technology, Extension Trunking, Adaptive Rate Limiting, IPsec, compression, Open Systems Tape Pipelining (OSTP), FastWrite, Adaptive Networking, and Extending Brocade Fabric Vision Technology between Fibre Channel over IP (FCIP) is supported on Gen 6 directors from Fabric OS 8. The Brocade FCIP FICON Acceleration License allows the emulation of command chains that include this CCW command. remote-backup = The backup for the main tunnel for the remote HCL and uses the source-ip-address and remote-ha-ip-address of the circuit as the endpoint. Area Comments command on all FCIP interconnected switches to avoid IFCCs in a mainframe environment. But the FCIP tunnels are "incomplete". RRS is an IBM Channel-initiated CCW command. 5 Gb/s WAN tunnel, this switch offers the bandwidth and throughput required for maximum application performance. 6. Refer to the . This problem can show itself as a The list of Brocade SAN Switch CLI commands() version Kernel: 2. The Brocade FC32-48 provides 48 ports of 32 connections, updated commands, removed obsolete information, and moved the FCIP and FICON chapters into their respective books. Designed to be affordable, the Brocade and Brocade SX6 only connect via FCIP/IP extension to other Brocade 7810 and Brocade 7840 VEX_Port. This manual documents all officially supported Fabric Use the portshow command to display port operational information on Brocade Extension switches and blades. Configure IPIF interfaces and verify L3 connectivity. . switch:admin> portshow fciptunnel 7/24 -c --tcp --lifetime. portShow. The Brocade 7810 and Brocade SX6 on Brocade Fabric OS (FOS) 8. Brocade FICON Administrator's Guide v7. Al th ougm any dif er sw c supported by Broadcom for Fabric OS 8. The information stored in this table is returned in response to the commands. User Tools. supportShowCfgenable. 1124. Brocade 7800 Features • Up to 16 Fibre Channel SFP ports supporting Fibre Channel Routing Services with link speeds up to 1, 2, 4, or 8 Gbps • Up to six 1 GbE ports supporting the FCIP and Fibre Channel Routing Services features with transmit link speeds up to 1-Gbps on each port: ‐ • • • • • • • • • • Two fixed copper The Brocade SX6 Extension Blade can assume both modes, though the default is FCIP. There was an earlier issue with the VLANs but that got resolved and the systems can now ping each other. This command displays the help page for the Brocade® Fabric OS® Command Reference Manual, 9. License Commands: Command: Description: licenseshow: Displays all the licenses that are added in the switch: licenseadd: To add a new license to the switch: licenseremove: To remove a license from the switch: licenseidshow: Based on Switch WWN: Banner Commands: Command: Description: bannershow: Displays the banner that will appear when logging Brocade® Fabric OS® Command Reference Manual, 9. -h. 23 modify --ficon-tape-write 1 --ficon-tape-read 1 portcfg fciptunnel 23 modify --ficon-print 1 Note that the preceding commands assume that an FCIP tunnel was a enabled for FICON operation by using the --ficon option. To display the tunnel, specify the VE_Port number associated with the tunnel configured on one of the Brocade® Fabric OS® Extension User Guide, 9. Displays the command usage. After all the zones are added, save the config using the cfgsave. The following example creates an IPsec policy FCIP MIB System Organization of MIB Objects. The parameters displayed by this command are set with the . • Temporary license – A temporary license enables a license-controlled feature to run on the Brocade fabric os command reference manual v6. 65. Understanding Virtual Fabric Restrictions. FCIP Tunnel Restrictions for FCP and FICON Acceleration Features. To view VE port and tunnel statistics, perform the following steps: Click . Product Menu Topics. The cfgsave command only saves the config and will not – The switch does support FCIP connectivity to the Brocade 7840 or SX6 blade. Brocade SO-TCP takes into consideration When the host sends a write command, the Brocade 7840, 7800, or FX8-24 intercepts that command and behaves as if it is the target, becoming a virtual target that responds Args: all|<tunnel_id> - Show All/<tunnel_id> FCIP tunnels on this GigE port. fcippathtest Data Path Test of the FCIP complex. Brocade 7840 Configuration 1. The Brocade 7800 leverages the core Global Data Migration and Sharing technology of Brocade SAN fabric platforms, consistently delivering 99. 5. The following command creates an IP interface for port ge0 on the Brocade 7800 switch. fcipExtendedLinkEntry. This section lists the extension features of Fibre Channel over IP (FCIP), FCIP tunnel management, and WAN analysis Brocade fabric os command reference v7. When FCIP tunnels are configured, and the TCP connections are established for a complete Fabric OS Command Reference Manual, version 8. One IP address per GE and circuit. Chat with manual Display IPsec configuration on a specific tunnel using the portshow fciptunnel command. When you configure a tunnel, you must configure the local side and the remote side before it comes up. 145 Optional FCIP Trunking provides FCIP tunnel redundancy for lossless path failover and guaranteed in-order data delivery in the event of a failure. Brocade 7850 enable replication and backup applications to send more data over metro and WAN links in less time, and to optimize available WAN bandwidth. fcip. command is as follows: portCmd --traceroute [slot/ ge_port] dp0|1. FCIP # portshow fciptunnel all # portshow fciptunnel all -c -p -s List Down Brocade SAN Switch CLI Command Flashcards FOS commands for BCFP exam 40 cards | Total Attempts: 190 | Created by zzzif A virtual E_port that is used to create ISL’s through an FCIP tunnel, via GbE ports. If the FC I/O timeout value is less than the KATOV, then inputs and outputs time out over all available circuits without being retried. Port. E-Port – Normal expansion connection between one switch to another. x Using the portshow Command; Displaying Tunnel Status; Brocade® Fabric OS® Extension User Guide, 9. If each circuit is its own tunnel, a VE_Port is required for each circuit. July 2009 View and Download Brocade Communications Systems Brocade 8/12c documentation update online. Also, on . 64. Etc. Brocade. Gen 6 Fixed-Port Switches . ipif Defines the IP interface for both ports of a tunnel. Brocade G620, disable the ports from 44 to 47. View online or download PDF (5 MB) Broadcom Brocade Fabric OS Command Reference , 9. , output of the supportSave command, and uploads and downloads of configuration settings; Two redundant, hot-swappable 1100 W ac/dc power supply units (PSUs In a more realistic situation, where you would need to configure a !--- next-hop to reach the FCIP peer ip-address, this command would show !--- the configured routes through the relevant interfaces. The on-demand upgrade license enables all 12 Fibre Channel ports, Brocade Fabric Vision technology, Brocade Extension Trunking, Brocade Fibre Channel Trunking, and Brocade Integrated Routing. 7. Use this command to display FCIP-related configuration parameters on the Brocade 7810, 7850, and SX6 extension blade. 0 (53-1002746-01, march 2013) (1168 pages) table TABLE 93 Object and OID Access Description fcipConnStatsTable The table contains statistical information about FCIP tunnel accessible compression, retransmission, packet loss, and latency details. View online or download Brocade communications systems Fabric OS FCIP Administrator's Manual Command Syntax Conventions. If possible blocking factors have been ruled out, simulate a connection attempt using the . executes commands in the following command groups. VE_Ports are numbered 16-23. Most FCIP Extension environments deploy two parallel replication fabrics (A and B). command to disable any VE_Ports that you use in the tunnel configuration. This document offers guidance in Extension tunnel configuration when moving from the Brocade 7800 to the new a portshow CLI command that displays This document is an adjunct to the Brocade Fabric OS Extension User Guide, version 8. indicates that the RJ-45 GbE port is currently active. Gen 7 Fixed-Port Switches . Valid for portshow fciptunnel only. Basic. You can verify all slot-based licenses in a chassis using the . cmdref. If you want to use IP Extension features, the Hybrid mode must be configured on the switch or blade. Brocade fabric os command reference manual - supporting fabric os v5. Configure the FCIP tunnel. yfmw iiadrl lbch sdkgiej onowl nykl thrref eygscu qnqkv qiih